300kw AC Resistive Load Bank Generator Test Equipment

Product Details
Customization: Available
After-sales Service: Other
Warranty: Other
Still deciding? Get samples of US$ 10000/Piece
Request Sample
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2014

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
62
Year of Establishment
2009-09-14
  • 300kw AC Resistive Load Bank Generator Test Equipment
  • 300kw AC Resistive Load Bank Generator Test Equipment
  • 300kw AC Resistive Load Bank Generator Test Equipment
  • 300kw AC Resistive Load Bank Generator Test Equipment
  • 300kw AC Resistive Load Bank Generator Test Equipment
Find Similar Products

Basic Info.

Model NO.
kplb-300
Rated Power
0--500kw
Frequency
50Hz/60Hz
Power Factor
PF = 1.0 or 0.8
Power Range
100kw to 2000kw
Load Step
10kw
Power
Electronic
Rated Voltage
110-480 VAC
Duty Cycle
Continuous
Color
Green/White/Blue/Red/Yellow
Cooling Mode
Forced Air-Cooled
Application
Generator, UPS, Battery
Transport Package
Wooden Packaging, Carton Packaging, PE Film with H
Trademark
keypower
Origin
China
Production Capacity
100pieces/Year

Product Description


 Product Details >>>>>>>>

KEYPOWER GENERATOR TESTER SPECIFICATIONS
Measurement Range Accuracy Resolution Overload
Voltage (V) 10.0~500.0V ± (0.4% reading+0.1%range) 0.1V 600V
Current (A) 0.030~5.000A  ± (0.4% reading+0.1%range) 0.001A 6A
Power

According to volt range 

&  current range

Power factor =1.0 <200W 0.1W  
± (0.4% reading+0.1% range) ≥200W 1W
Power factor =0.5 ≥2kW 10W
± (0.8% reading+0.2% range)  
Power Factor 0.20~1.00 ±0.02 0.001  
Frequency 45~65Hz ±0.2Hz 0.01Hz  
Running Time 99h59m ±2min/hour 1 minute  
Energy
 (kWh)
99999kWh  Power factor= 1.0 0.001kwh  
± (0.4% reading+0.1% range)
Power factor=0.5
± (0.8% reading+0.2% range)

Harmonic Analysis 

(%)

2-50 times 

and total harmonic

     

 

Models You Can Choose
Model

Testing 

capacity

Type 

of

 load

Duty

Cooling 

system

Phase

Rated 

Testing 

Voltage

Rated

 Frequency

Dimensions   

   (L*W*H)

 (mm)

Weight

 (kg)

KPLB-100 0 - 100 kw

Resistive 

or 

Reactive, 

 PF = 

1.0 or 0.8

Continuous

Industrial 

grade 

axial fan

Available

 at both 

single 

and 

three 

phase

110-480 

VAC

50/60 Hz 960*960*1400 320
KPLB-200 0 - 200 kw 1300*1200*1570 500
KPLB-300 0 - 300 kw 1600*1200*1700 900
KPLB-400 0 - 400 kw 1600*1400*1700 1000
KPLB-500 0 - 500 kw 2100*1560*1700 1200
KPLB-600 0 - 600 kw 2100*1560*1700 1300
KPLB-700 0 - 700 kw 2100*1560*1800 1400
KPLB-800 0 - 800 kw 2100*1660*1900 1600
KPLB-1000 0 - 1000 kw 2200*1900*2150 2000
KPLB-2000 0 - 2000 kw 20 ft container 6000

 


300kw AC Resistive Load Bank Generator Test EquipmentSpecifications

100-2000KW Load Bank for Generator Load Test:

1.Premium components

2.Durable and reliable

3.Easy to transport 
Load bank is a simulating load test equipment used for generators, 

UPS, battery banks etc power systems load test. 

1. Resistive type of load, PF = 1.0. Stainless steel sheathed elements manufactured from high grade magnesium oxide.
2Rated testing voltage: AC 3P4W, 110-480V 50/60 Hz. 
3. Cooling mode: Forced air-cooled, fans mounted on the side of the load bank blow horizontally. Testing power or external utility power supply for fans. 
4. Working mode: Load step control
Total testing capacity ranges from 0kw to the max consisting of 10kw, 20kw, 50kw, 100kw load setting switches plus a 0-10kw fine-tuning knob. From 0kw to the max, any load combination is achievable. Load step resolution is 10kw. 
5. Load bank features world-famous components to ensure reliable performance and longer service life including:
SCHNEIDER contactors. 
Siemens switches, knobs and indicators. 
ABB Circuit breakers. 
OMRON intermediate relays. 
PHOENIX terminal blocks. 
6.  Parameter measuring accuracy grade: 0.3 
7. Load control accuracy: &plusmn; 5%. 
8. Load bank protections: Over heating protection, cooling fans failure protection and over load protection with alarm. 
9. Control mode: Two control modes available:
A)Local manual control;
B)Optional: Manual control via a remote control panel (max control distance is 30m). 
10. Parameter display and measurement:
Control panel contains a LOVATO Multifunction Electricity Meter displaying voltage, current, load power, reactive power, apparent power, power factor, frequency etc.
(Optional: A professional generator tester displays and measures all sorts of steady, dynamic parameters as well as harmonic wave, can be connected to a PC for data recording and test report printing). " 
11. Operating environment:
Altitude: &le; 3000m above sea level. Ambient temp: -10~+50 ºC
Relative humidity: &le; 80% ventilated environment without explosive or corrosive dust. Not allowed to use in rainy outdoor environment.

Any question, please contact me directly. 
300kw AC Resistive Load Bank Generator Test Equipment

 

 

 

 

 

300kw AC Resistive Load Bank Generator Test Equipment

300kw AC Resistive Load Bank Generator Test Equipment300kw AC Resistive Load Bank Generator Test Equipment

 

Fuzhou GFF KEYPOWER Equipment Co., Ltd is a dedicated manufacturer with more than a decade's experience in manufacturing and developing generator set and load bank.KEYPOWER is located in the coastal city of Fuzhou which lies to the west of Taiwan strait, with factory address at No. 1, Gaoqi Industrial Park, Nanyu town, Minhou county, Fuzhou, the park covers an area of 66,000 square meters including diesel generator assembling workshop of more than 8,000 square meters. With a professional team consisting of 150 qualified staff members as well as state-of-the-art processing equipments and innovative design philosophy,KEYPOWER manufactures and sells 3000-5000 units of high quality generator sets and load banks every year.  

 

 

Load Bank FAQ

1. What is a load bank?


A load bank is a device designed to provide electrical loads for testing various power sources, Including Engine Generators, Battery Systems, UPS Systems, Inverters, Ground Power Units, Auxiliary Power Units, Aircraft Power Generators, Wind Generators, and Hydro Generators etc.


2. Why is Load Testing Important?
Load bank testing will save your time and money in the long run. It is how you determine the operating status of your primary power systems. It's also how you exercise backup systems to ensure they will be available when called upon. Load testing at start-up and during commissioning and maintenance will detect problematic conditions before they escalate and cause downtime.

 

3. What are the different types of load banks?
Resistive, Inductive, capacitive and Resistive/Inductive combined

 

4. Can the Load Bank test at single phase?
Yes, but the rating available is 1/6 of the rated testing capacity.

 

5. Is it possible to synchronize multiple Load Banks for Testing?
Yes. Multiple Load Banks can be synchronized to test one generator but one Load Bank is not able to test multiple generators at the same time.

 

6. What is the operating environment for Keypower Load Bank?
Our Load Banks are to be applied where altitude ≤2500m above sea level,
ambient temp within -15ºC ~ +55ºC and relative humidity ≤98%.

 

7. What is the different between Keypower standard load bank and dual voltage?
For example, a KPLB-500 @400V can test full 500kw @400V, and derating to 165kw only @230V 3 phase. Dual voltage KPLB-500 can test full 500kw @400V and @230V. 

8. What is generator tester 8961?
The generator tester 8961 is used for recalling the data from the generators you are testing. Then it can create the test report and sine wave forms. It is good for generator manufacturer and project commissioning.

 

9. Is the load bank weatherproof?
Standard type isn't weatherproof, but optional air discharge duct and cam-lock connectors can be fitted on it to enable weatherproof.

 

10. Does the load bank support remote monitoring and control?
Standard type doesn't support, but optional programmable Mitsubishi PLC can be fitted to support remote monitoring and control on laptop.